2024 International Bridge Building Contest Rules
These rules have been developed by the International Bridge Building
Committee for the Forty-Sixth International Bridge Building
Contest to be held on Saturday, April 27 in New Philadelphia, Ohio, USA.
If you have a question about the contest that is not answered by our
FAQ, please direct it to Paul
Dykshoorn at pdykshoo@kent.edu.
In order to receive official wood and participate in this contest,
a High School student must have placed first or second in a Regional
Contest and be reported, by the Regional Coordinator, to Vey Wagner
by e-mail: vwagner6@kent.edu. Students may
participate in person, by proxy or by mail entry.
This is a contest for individual high school students, not
teams. The object of this contest is to see who can design, construct and
test the most efficient bridge within the specifications. Model
bridges are intended to be simplified versions of real-world bridges,
which are designed to permit a load to travel across the entire bridge.
In order to simplify the model bridge design process, the number of
loading positions is reduced, and to allow the contest to proceed in a
reasonable amount of time, only one loading position is actually tested.
These simplifications do not negate the requirement that the bridge must
be designed to accept a load at any of the positions. Bridges determined
by the judges to not meet this requirement will be disqualified and tested
as unofficial bridges.
1. Materials
-
The bridge must be constructed only from the official
3/32-inch square cross-section basswood included in the kit
and any commonly available adhesive.
-
The official basswood may be notched, cut, sanded or laminated in any
manner but must still be identifiable as the original official
basswood.
-
No other materials may be used. The bridge may not be stained,
painted or coated in any fashion with any foreign substance.
2. Construction
-
The bridge mass shall be no greater than 25.00 grams.
-
The bridge (see Figure 1) must span a gap (S) of 300. mm,
be no longer (L) than 400. mm,
be no wider (W) than 80. mm,
and be no taller than (H) than
150. mm above the support surfaces. The bridge structure
may not project below the support surfaces.
-
The loading plane (P) shall be
horizontal and shall lie on the physical top of the bridge between
100. mm and 150. mm above the support surfaces.
-
The bridge must be constructed to provide a horizontal support
surface so that the loading plate (see section
3 below) without
rod attached can be pushed smoothly along the loading plane from one
loading point to the other: 30. mm and 50. mm on either
side of the center of the 300. mm span along the longitudinal
axis of the bridge.
3. Loading
-
The load will be applied downward, from below, by means of a
40. mm square plate (see Figure 2). The plate will have a
thickness (t) of at least 6 mm but less than 13 mm
and will have an up to 9.53 mm (3/8 inch) diameter threaded
rod attached from below at its center with a standard hex nut. The
plate will be horizontal with two sides parallel to the longitudinal
axis of the bridge.
-
The load will be applied on the longitudinal axis of the bridge at one
of two loading points: 30. mm and 50. mm on either side of
the center of the 300. mm span.
-
On the day of the competition, the judges will randomly decide which
of the two loading positions will be used; it will be the same for
all bridges.
4. Testing
-
On the day of the competition, contestants will center their bridge
on the support surfaces with the threaded rod projecting from below
at the designated loading position.
-
The loading plate will be placed from above on the threaded rod
with two sides parallel to the longitudinal axis of the bridge and
secured with a hex nut.
-
The load will be applied from below, with the contestant rotating the
Vernier testing machine load wheel until bridge failure is sensed
(see 4d). Competition loading will stop at 50. kg.
-
Bridge failure is defined as the inability of the bridge to carry
additional load as sensed by the Vernier testing machine.
-
The bridge with the highest structural efficiency, E, will be
declared the winner. Bridges failing above 50. kg will be
considered to have held 50. kg for efficiency calculation.
E = Load supported in grams (50,000g maximum) / Mass of bridge in grams
5. Qualification
-
All construction and material requirements will be checked prior to
testing. Bridges failing to meet these requirements will be
disqualified. If physically possible, disqualified bridges may be
tested as exhibition bridges at the discretion of the builder and the
contest directors.
-
If, during testing, a condition becomes apparent (i.e., use of
ineligible materials, inability to support the loading plate, bridge
optimized for a single loading point, etc.) which is a violation of
the rules or prevents testing as described above in Section 4, that bridge shall be disqualified.
-
Decisions of the judges are final; these rules may be revised as
experience shows the need. Please check our web site,
http://bridgecontest.phys.iit.edu
after February 12, 2024, to learn whether any changes have been made.
Last update: October 5, 2023
[ Bridge Contest Home ] [ International Contest ] [ Chicago Regional Contest ]
[ Region Locator ] [ Official Documentation ] [ Other Bridge Links ]
For further information, contact: Prof. Carlo Segre -
segre@iit.edu,
Illinois Institute of Technology
© International Bridge Building Committee, 2024